Answer first

For an illustrative home with an 8kW design heat loss, averaging half that load over 24 hours would mean about 96kWh of useful heat. At a cold-day COP of 2.5, the heat pump would use roughly 38.4kWh. At 26.11p/kWh that is about £10.03 for the day, before any standing charge.

That is deliberately an example, not a typical-home claim. A smaller, better-insulated home may need far less heat; a large exposed home may need more. Weather, wind, hot water, defrost and backup heat also matter.

2.44

Mean whole-system COPH4 on the monitored project’s coldest day

View source
−0.4°C

Mean outdoor temperature for that coldest-day analysis

View source
24 hours

A whole-day estimate must account for changing load, not assume full output all day

View source
Ask about your home · no obligation

Discuss heat-pump costs and savings for your home

Share your postcode, current heating and the bill question you want answered. FLO can explain what needs measuring before any saving figure is treated as realistic.

Phone or email (required)

Enter at least one so FLO can respond to your enquiry.

What happens next: FLO reviews your question and property details, then contacts you to discuss them.

Start with your own questionNo survey commitmentMCS certified · NAP-689870800 043 1188

Sending this form asks FLO to respond to your enquiry. Privacy policy

Rated capacity is not daily consumption

An 8kW heat pump does not normally draw 8kW of electricity continuously. The rating describes heat output at stated conditions. On most hours the building load is below its coldest design point, and a well-controlled inverter-driven unit modulates its output.

Multiplying the model rating by 24 therefore exaggerates consumption. Start with the building heat needed across the actual day, add hot water and then divide by the efficiency achieved while delivering it.

A worked cold-day example

Assume a surveyed design heat loss of 8kW at the local design temperature. If conditions and internal gains mean the home averages 4kW across one cold day, it needs 4 × 24 = 96kWh of space heat. At COP 2.5, that requires 38.4kWh of electricity.

At 26.11p/kWh the space-heating cost is £10.03. Add whatever electricity the system uses for hot water, circulation and any deliberate backup heat. Changing the average load to 3kW reduces the example to 72kWh of heat and 28.8kWh of electricity at the same COP.

Keep in mind: Use the unit rate on your tariff. Ofgem publishes averages, but the household’s actual rate and time-of-use periods decide the bill.

Cold weather reduces efficiency, but not to one fixed number

The Electrification of Heat project found a mean COPH4 of 2.44 on the coldest analysed day, when the mean temperature was −0.4°C. That shows useful heat was still being delivered at more than twice the electrical input at that system boundary, on average across the sample.

Individual results varied. Required water temperature, defrost cycles, unit selection, emitter capacity and system controls all influence cold-weather performance. A quote should show capacity and efficiency at relevant design conditions, not only a mild-weather figure.

Why one expensive day does not predict the year

Annual cost is the sum of mild, average and cold days. A home may have several high-consumption days during a cold spell but spend much of the heating season at lower load and better efficiency. Seasonal performance is more useful for an annual budget.

Compare equivalent comfort as well. A household that heats more rooms for longer after installation may use more useful heat even if the system is efficient. That is a lifestyle and comfort change, not automatically a fault.

The questions to ask before accepting a winter-cost claim

A defensible estimate should let you identify the building load, the weather assumption and the system performance assumption. If one of those is missing, the final pound figure is difficult to test.

  • What is the calculated design heat loss?
  • What outdoor temperature is used for the location?
  • What capacity and COP does the selected unit provide there?
  • What flow temperature is assumed?
  • How are hot water, defrost and backup heat treated?
  • Which tariff and date support the price calculation?

What to read next

Related answers and services

Questions people also ask

Do heat pumps stop working below freezing?+

No. Correctly selected air-source heat pumps operate below freezing, but capacity and efficiency vary with outdoor and water temperatures and must be checked in the design data.

Is defrost wasted electricity?+

Defrost is a normal part of air-source operation in certain cold, damp conditions. Excessive or problematic cycling should be investigated, but the presence of defrost is not itself a fault.

Should I turn the heat pump off during an expensive cold spell?+

Usually not simply because it is cold. Allowing the home to cool deeply can require higher output and temperatures later. Use the commissioned controls and seek advice before changing the strategy.

Evidence used for this answer

Figures are explained in context and links go to the independent source. Prices, tariffs, scheme rules and standards can change, so check the source again before making a financial or technical decision.