Answer first
Current Scottish guidance permits one domestic air-source heat pump on a dwelling or within its curtilage, subject to limits on protrusion, road-facing positions, height, designated places and compliance with MCS 020. Listed-building curtilage and World Heritage Sites are excluded from these rights.
Conservation-area installations have specific restrictions, and private title or owner consent is separate from planning. Ask the local planning authority for written advice when status or interpretation is uncertain.
Current class 6H permitted-development limit for the same building or curtilage
View sourceMaximum stated protrusion from the relevant external surface
View sourceCurrent MCS 020 calculated sound limit at all assessment positions
View sourceHave FLO check the proposed position during your survey
Tell FLO about the property, current heating and the point you need resolved. A £0 home survey can turn the general answer into a room-by-room design and written quote.
Check every permitted-development limitation
For a unit within the curtilage, development is not permitted forward of a principal or road-facing side elevation, and the resulting structure must not exceed three metres. A unit attached to the dwelling must not protrude more than one metre.
The rules also limit the property to one ASHP under this class. A second unit or a proposal outside the limits may need a planning application rather than being impossible.
Designated places need extra care
Within a conservation area, the current guidance requires an ASHP on the dwelling to be at ground-floor level and on the rear elevation. Permitted-development rights do not apply in a World Heritage Site or within the curtilage of a listed building.
Listed-building consent may also be relevant where historic fabric or character is affected. Confirm the building and curtilage status rather than assuming the postal address tells the whole story.
Complete the sound assessment
MCS 020 uses declared sound power, distance, reflections, barriers and assessment positions to calculate compliance. The current standard uses a 37.0dB(A) result limit at all assessment positions for this route.
Moving the unit, selecting a quieter model or using an appropriate barrier can change the result, but mitigation must not obstruct airflow, service access or manufacturer requirements.
Keep planning and private rights separate
A permitted-development installation can still require a landlord, factor, co-owner or titleholder’s consent. Building standards, electrical rules and network notification also remain separate processes.
Record the address search, proposed position, sound calculation and any planning correspondence in the project file. If relying on verbal advice for a marginal case, ask how to obtain formal confirmation.
What to read next
Related answers and services
Questions people also ask
Does every heat pump avoid planning permission?+
No. It must meet every permitted-development limit and condition; otherwise a planning application may be required.
What if my home is listed?+
The current domestic ASHP permitted-development right does not apply within the curtilage of a listed building; seek planning and heritage advice.
Is the old one-metre boundary rule still the Scottish test?+
Use the current Scottish Government circular and current MCS 020 standard, not an old article or rule from another UK nation.
Evidence used for this answer
Figures are explained in context and links go to the independent source. Prices, tariffs, scheme rules and standards can change, so check the source again before making a financial or technical decision.
- Scottish Government: householder permitted development rightsOfficial Scottish limits and conditions for domestic air-source heat pumps, including siting, designated places and MCS 020.
- MCS 020: air-source heat-pump sound calculation standardCurrent permitted-development sound assessment method for air-source heat-pump installations.